110.7Wiring Integrity

Article 110GENERAL REQUIREMENTS FOR ELECTRICAL INSTALLATIONS

NEC 110.7 - Wiring Integrity: Don't Be That Electrician

The Plain-Language Breakdown

Alright, listen up. Section 110.7 is basically the NEC's way of saying, "When you're done with your work, it better actually work."

This is the electrical equivalent of "clean up after yourself" meets "don't burn the building down." When you slap on that final cover plate and call it a day, your installation needs to be:

  1. Free from short circuits - Hot wires aren't playing footsie with each other
  2. Free from ground faults - Your hot conductors aren't making unauthorized friendships with grounded surfaces, equipment, or the ground wire
  3. Free from random ground connections - The only things touching ground are what the Code specifically tells you can touch ground

Think of it this way: When you finish wiring a circuit, it should sit there quietly doing its job like a good employee. It shouldn't be sparking, tripping breakers, or starting fires the second you flip the switch. Your work needs to be electrically sound - not just "looks good from my truck."

This section is basically the NEC holding up a mirror and asking, "Did you actually test your work, or are you just hoping for the best?" Because hoping ain't a testing method, chief.

Key Takeaways (The Stuff That Actually Matters)

Your completed installation must be free from:

  • Short circuits (phase-to-phase or phase-to-neutral faults)
  • Ground faults (unintentional current paths to ground)
  • Unauthorized ground connections (grounding things that shouldn't be grounded)

"Completed wiring installations" means when you're DONE - not "good enough for now"

Ground connections are only allowed where the Code specifically requires or permits them - you don't get to freelance this stuff

This applies to ALL electrical installations - doesn't matter if it's a $50 receptacle swap or a $5 million industrial job

Testing is implied - you can't certify your work is free from faults if you never tested it (looking at you, "visual inspection only" crowd)

Real-World Jobsite Scenarios

Scenario 1: The "It Worked Yesterday" Defense

You're finishing up a commercial kitchen rough-in. Everything's stapled, boxed, and beautiful. You flip the breaker and... BOOM - it trips immediately.

Turns out your apprentice drove a staple straight through the jacket of a 12/2 and pinched the hot and neutral together. That's a short circuit, brother. Section 110.7 says this installation ain't "complete" until that short is found and fixed.

The GC doesn't care that "it was fine until we stapled it." The Code says you deliver a working, fault-free installation. Period.

The Fix: Megger test your circuits before you close up walls. Find problems when they're easy to fix, not after the drywall crew leaves.


Scenario 2: The Mystery Ground Fault

You're troubleshooting a maintenance shop where a 480V, 3-phase motor keeps tripping the ground fault protection. Turns out someone "temporarily" mounted the motor on wet concrete without a proper mounting pad, and the motor frame is energized from deteriorated insulation.

That's a ground fault - unintentional current flow to ground. Section 110.7 says this installation is deficient and needs correction. You can't just "turn up the ground fault trip setting" and call it good. Fix the actual problem.

The Lesson: Ground faults aren't suggestions to work around - they're dangerous conditions that violate 110.7 and need immediate correction.


Scenario 3: The Helpful Handyman

You're doing service work at an older industrial facility. You notice someone bonded the neutral to the equipment ground in a subpanel 200 feet from the main service.

"But it's grounded!" says the maintenance guy who did it. Yeah, and it's also WRONG.

That's an unauthorized ground connection. The Code is very specific about where neutrals can bond to ground (spoiler: Article 250 covers this in painful detail). Random ground connections create parallel neutral return paths, which means neutral current on your equipment grounding conductors. That's how people get shocked touching "grounded" equipment.

Section 110.7 says the only ground connections allowed are the ones the Code specifically permits. Everything else is a violation.

The Fix: Remove that bonding jumper and educate folks that "more grounding" isn't always better - it needs to be correct grounding.


Scenario 4: The Inspector's Favorite Question

Inspector shows up for final inspection on a resi job. Before even pulling out his flashlight, he asks: "Did you test it?"

You: "Uh, I turned on all the switches..."

Inspector: "That's not testing. Show me your megger results or show me you've continuity tested. Section 110.7 requires completed installations to be free from faults. How do you know you've met that requirement?"

You: awkward silence

The Reality: Professional electricians TEST their work. Insulation resistance testing, continuity testing, proper operation under load - that's how you prove your installation meets 110.7. The inspector isn't being a jerk; they're holding you to the standard you're supposed to already meet.


What to Study (Exam Prep Edition)

If you're taking your Journeyman or Master's exam, here's what they love asking about 110.7:

High-Probability Exam Questions:

  1. Definition questions: "What three conditions must completed wiring installations be free from?"

    • Answer: Short circuits, ground faults, and unauthorized ground connections
  2. Application questions: "An electrician completes an installation but the circuit trips immediately when energized. Does this installation comply with 110.7?"

    • Answer: No - it's not free from faults if it trips on energization
  3. Ground connection questions: "Where are ground connections permitted in electrical installations?"

    • Answer: Only where required or permitted elsewhere in the Code (usually leads into Article 250 questions)
  4. Scenario-based questions: They'll describe a fault condition and ask if it violates 110.7

    • Know your definitions: short circuit vs. ground fault vs. unauthorized ground connection

Study Tips:

📖 Cross-reference Article 250 - That's where most of the "required or permitted" ground connections are detailed

📖 Understand the difference:

  • Short circuit = conductor-to-conductor fault (hot-to-hot, hot-to-neutral)
  • Ground fault = conductor-to-ground fault (hot-to-equipment, hot-to-earth)
  • Unauthorized ground = bonding something to ground that shouldn't be bonded there

📖 Remember the word "completed" - This applies when you're DONE, not during rough-in

📖 Know your testing methods - Be ready to explain how you'd verify compliance (insulation resistance testing, continuity checks, etc.)

Practice Question:

"According to 110.7, completed wiring installations must be free from ground faults and short circuits, and must not have any connections to ground except where _______ elsewhere in the Code."

Answer: "required or permitted"

(They love fill-in-the-blank questions with this section)


The Bottom Line

Section 110.7 is refreshingly simple: Do your job right.

When you finish an installation, it should be electrically sound. No shorts, no ground faults, no cowboy ground connections. Test your work. Fix your faults. Deliver installations that work properly and safely.

This section is basically the NEC reminding us that we're professionals, not parts changers. Anyone can throw wire in a wall. Electricians deliver installations that meet 110.7.

Now get out there and make your work something you'd be proud to put your name on. Because technically, you already did - it's called a permit card.

Stay safe, test your work, and remember: The only good surprise at final inspection is no surprises.


Your wire nuts should be tight, your bends should be pretty, and your installations should comply with 110.7. That's the trade.

NEC Reference: Section 110.7 · 2026 NEC (NFPA 70)